Electromagnetic RFID Switch 600N (MGL-2SS)
The MGL-2SS is a magnetic guard locking safety switch with coded RFID technology, designed to deliver high functional safety and reliable electromagnetic guard interlocking in industrial applications. Housed in a mirror-polished 316 stainless steel enclosure with a pre-wired cable and gland, it is ideally suited for food processing, packaging, and pharmaceutical applications. Its IP69K rating allows the switch to withstand high-pressure hosing with detergent at high temperatures.
- Manufactured from 316 Stainless Steel with a Mirror Polished Finish
- Holding Force Rated to F1Max 600N (60Kg)
- Ingress Protection up to IP69K
- Functions as a Power-to-Lock Device
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part Number | Part Description |
|---|---|
| 460001 | MGL-2SS-U 5m |
| 460002 | MGL-2SS-U 10m |
| 460004 | MGL-2SS-M 5m |
| 460005 | MGL-2SS-M 10m |
| Important Note |
|---|
| As a power-to-lock device, the MGL range requires careful consideration in the event of power loss, particularly on machines where hazardous motion or risk remains present during run-down before the danger is fully removed. |
| Technical Data | |
|---|---|
| Approvals | TUV, cULus |
| Coding Level according to EN ISO 14119 | M = Low / U = High |
| Technology | Electro-Magnetic, RFID, Power to Lock |
| Holding Force | (F1 max.) 600N |
| Housing Material | 316 Grade Stainless Steel |
| Contact Configuration | 2 N/C + 1 N/O, Voltage-Free Outputs |
| Dielectric Withstand | 250V.ac |
| Insulation Resistance | 100 Mohms |
| Switching Distance | Sao 1mm Close / Sar 10mm Open |
| Switching frequency | 1.0 Hz maximum |
| Approach speed | 200mm/m to 1000mm/s |
| Temperature Range | -25 ... +40 °C |
| Enclosure Protection | IP67, IP69K |
| Cable Type | PVC 8 core 6mm OD |
| Mounting Bolts | 2 x M5 Tightening torque 1.0 Nm |
| Power Supply | +24Vdc ± 10% (SELV / PELV) |
| Maximum Switched Current (outputs) | 200mA (Minimum internal resistance 8.5 Ohms) |
| Characteristic Data according to EN ISO13849-1 | |
|---|---|
| Performance Level | e (If both channels are used in combination with a SIL3/PLe control device) |
| Category | Cat4 |
| MTTFd | 1100a |
| Diagnostic Coverage DC | 99% (high) |
| Number of operating days per year | dop = 365d |
| Number of operating hours per day | hop = 24h |
| B10d | Not mechanical parts implemented |
| INFORMATION WITH REGARD TO UL508 |
|---|
| Type 1 Enclosures. Maximum temperature 40ºC. Maximum output 24V.dc 200mA. Powered by Class 2 or equivalent. WARNING: Hot surface – risk of burn if used at ambient temperature of +40C degrees. (Affix a warning label to the switch). |