Electromagnetic RFID Switch 1000N (MGL-2P)

The MGL-2P is a magnetic guard locking safety switch with coded RFID technology, designed to provide high functional safety and reliable electromagnetic guard interlocking in industrial applications. Housed in high-specification polyester with pre-wired cable and gland, it is ideally suited to machine guarding systems requiring guard monitoring with a high level of tamper resistance.


  • Manufactured from High Specification Polyester Plastic
  • Holding Force Rated to F1Max 1000N (100Kg)
  • Ingress Protection up to IP67
  • Functions as a Power-to-Lock Device
Part Number Part Description
461001 MGL-2P-U 5m
461001-ZR MGL-2P-U 5m – Zero Residual Magnetism
461002 MGL-2P-U 10m
461004 MGL-2P-M 5m
461005 MGL-2P-M 10m

Important Note
As a power-to-lock device, the MGL range requires careful consideration in the event of power loss, particularly on machines where hazardous motion or risk remains present during run-down before the danger is fully removed.

Technical Data
ApprovalsTUV, cULus
Coding Level according to EN ISO 14119M = Low / U = High
TechnologyElectro-Magnetic, RFID, Power to Lock
Holding Force(F1 max.) 1000N
Housing MaterialBlack Polyester
Contact Configuration2 N/C + 1 N/O, Voltage-Free Outputs
Dielectric Withstand250V.ac
Insulation Resistance100 Mohms
Switching DistanceSao 1mm Close / Sar 10mm Open
Switching frequency1.0 Hz maximum
Approach speed200mm/m to 1000mm/s
Temperature Range-25 ... +40 °C
Enclosure ProtectionIP67
Cable TypePVC 8 core 6mm OD
Mounting Bolts2 x M5 Tightening torque 1.0 Nm
Power Supply+24Vdc ± 10% (SELV / PELV)
Maximum Switched Current (outputs)200mA (Minimum internal resistance 8.5 Ohms)

Characteristic Data according to EN ISO13849-1
Performance Levele (If both channels are used in combination with a SIL3/PLe control device)
CategoryCat4
MTTFd1100a
Diagnostic Coverage DC99% (high)
Number of operating days per yeardop = 365d
Number of operating hours per dayhop = 24h
B10dNot mechanical parts implemented

INFORMATION WITH REGARD TO UL508
Type 1 Enclosures. Maximum temperature 40ºC. Maximum output 24V.dc 200mA. Powered by Class 2 or equivalent. WARNING: Hot surface – risk of burn if used at ambient temperature of +40C degrees. (Affix a warning label to the switch).