Belt Alignment Switch (Stainless Steel, Heavy Duty, 35mm Diameter with 230mm Length Roller)
IDEM’s stainless steel heavy duty conveyor belt alignment switches are designed for use on the running edge of conveyor belts. They are suitable for both indoor and outdoor use and can withstand extreme weather conditions.
- Body Material: Stainless Steel 316; ideal for exposure to chemical cleaning agents
- Ingress Protection: IP69K
- Contacts: 1NC + 1NO Warning Signal / 1NC + 1NO Stop Signal
- Connectivity: 4 x M20 or ½” NPT Conduits
- Part Numbers
- Technical Specifications
- Technical Drawings
- Downloads
- Accessories
- Related Products
- Sistema & Certificates
| Part No. | Part Description |
|---|---|
| 501005 | Belt Switch SS 35mm Roller Long M20 2NC 2NO |
| 501006 | Belt Switch SS 35mm Roller Long 1/2″ NPT 2NC 2NO |
| 501007A | Belt Switch SS 35mm Roller Long M20 2NC 2NO 24v LED |
| 501007B | Belt Switch SS 35mm Roller Long M20 2NC 2NO 110v LED |
| 501007C | Belt Switch SS 35mm Roller Long M20 2NC 2NO 230v LED |
| 501008A | Belt Switch SS 35mm Roller Long 1/2″ NPT 2NC 2NO 24v LED |
| 501008B | Belt Switch SS 35mm Roller Long 1/2″ NPT 2NC 2NO 110v LED |
| 501008C | Belt Switch SS 35mm Roller Long 1/2″ NPT 2NC 2NO 230v LED |
| Technical Data | |
|---|---|
| Approvals | cULus |
| Technology | Belt Alignment Switch |
| Housing Material | 316 Grade Stainless Steel |
| Operating Temperature | -25 ... +80 °C |
| Enclosure Protection | IP67, IP69K (NEMA 6) |
| Conduit entries | 4 x M20 or 4 x ½ “ NPT |
| Mounting | 4 x M5 |
| Torque settings | Mounting M5 4.0 Nm Lid T20 Torx M4 1.5 Nm Terminals 1.0 Nm |
| Vibration resistance | 10-500Hz 0.35mm |
| Shock resistance | 15g 11ms |
| Mechanical Reliability | 150,000 operations at 100mA load |
| Switching range | WARNING signal 10 to 18 degrees / STOP signal 15 to 35 degrees |
| Operating Torque range (adjustable) | Medium Duty 1.8Nm to 2.8Nm / Heavy Duty 3.0Nm to 5.0Nm |
| Maximum tilt angle (mounting angle) | 30 degrees |
| Maximum Deflection | 65 degrees |
| Safety Contact type | IEC 60947-5-1 Double break Type Zb |
| Termination | Clamp up to 2.5 sq. mm conductors |
| Rating | Utilisation Category : AC15 |
| Operational Rating | AC15 A300 240V. 3A. / 120V. 6A. ac 24V. 2.5A dc |
| Thermal Current (Ith) | 10A |
| Rated Insulation Voltage (Ui) | 500V |
| Withstand Voltage (Uimp) | 2500V |
| Short Circuit Overload Protection | Fuse Externally 10A. (FF) |
| Information with regard to UL 508 |
|---|
| Type 1 Enclosures. Use 16 - 14AWG copper conductors, rated 70ºC only. Intended for same polarity use. Electrical Rating: A300 240V.ac 3A. (6,000 cycles) 120V.ac 60A. Making 6A. Breaking PF >0.38 (100,000 cycles) 240V.ac 10A. carry only. Torque 7lb/in (0.8Nm) LED powered by LVLC or Class 2 only. Earth bonding terminal inside enclosure if required. |
| The device is permitted to control more than one load provided the total load connected to the line at one time does not exceed 1440 volt-amperes, or have a current rating greater than 30 amperes at 51-150 volts or 20 amperes at 151 to 300 volts. |